Supplying Fennoscandian power grids, wind farms, data centers, and telecom towers with deep-driven copper-bonded rods, exothermic weld kits, and Type 1+2 surge arresters rated for high-resistivity bedrock.

254 μm
Min Copper Coating
100 kA
Impulse Current Rating
-45 °C
Arctic Frost Rating

Request Engineering Quote (RFQ)

Submit project specs or BOM list to our Helsinki desk for same-day pricing and stock allocation.

Core Equipment Stock (Helsinki Logistics Center)

SKU: GS-CB16-1500-FI

Threaded Copper-Bonded Earth Rod

High-tensile steel core with 99.9% pure electrolytic copper coating engineered for moraine and glacial till soils.

Diameter / Length16 mm / 1500 mm
Copper Thickness≥ 254 microns
Tensile Strength600 N/mm²
SKU: GS-EXW-90G-FI

Exothermic Weld Metal & Graphite Mold

Creates permanent molecular copper-to-copper or copper-to-steel bonds immune to freeze-thaw cycles.

Cartridge Weight90g / 115g / 150g
Reaction Temp> 2500 °C
Mold Lifespan70–90 Welds
SKU: GS-SPD-T12-4P

Type 1+2 Industrial Surge Arrester (3+1)

Pluggable DIN-rail SPD with thermal disconnector and remote signaling contact for main distribution boards.

Max Discharge (Imax)50 kA (8/20 μs)
Lightning Current (Iimp)12.5 kA (10/350 μs)
Operating Temp-40 °C to +80 °C
SKU: GS-BRS-CPL16

High-Strength Silicon Bronze Coupler

Counter-bored heavy-duty coupling sleeve ensuring direct rod-to-rod contact during deep hydraulic installation.

Thread SizeM16 / 5/8" UNC
MaterialCuSi3Mn1 Bronze
Corrosion RatingEN 62561-1 Class H
SKU: GS-GEM-25KG

Conductive Carbon Earthing Backfill

Low-resistivity graphite-bentonite compound for drilled boreholes in Finnish granite and gneiss bedrock.

Resistivity< 0.12 Ω·m
Package Weight25 kg Moisture-Proof Bag
LeachingZero Groundwater Impact
SKU: GS-PIT-POLY-AR

Frost-Resistant Polymer Earth Inspection Pit

Load-rated ground access chamber with removable copper test bar for periodic earth resistance testing.

Static Load Rating5000 kg (50 kN)
Dimensions250 × 250 × 300 mm
Cold Impact RatingDown to -45 °C

Vertical Rod Grid Resistance Estimator

Estimated Grid Resistance (Rg)
12.63 Ω
For high-resistivity moraine or granite terrain, consider deep borehole electrodes with conductive backfill (GS-GEM-25KG) to achieve < 4 Ω.

Finnish & European Technical Standards

Standard Code Scope & Application Verification Status
SFS 6000 Low-voltage electrical installations — Finnish national requirements for protective earthing COMPLIANT
SFS-EN 62561-2 Lightning protection system components (LPSC) — Conductors and earth electrodes VERIFIED
SFS-EN 62305 Protection against lightning — Risk management and structural grounding grids VERIFIED
IEEE Std 837 Qualifying Permanent Connections Used in Substation Grounding (Exothermic Welds) VERIFIED
SFS-EN 61643-11 Low-voltage surge protective devices — Performance requirements and cold-climate testing VERIFIED

Registered Office & Nordic Logistics Hub

Corporate Headquarters (Finland)

  • Legal EntityGround Store Pro Oy
  • Street AddressMannerheimintie 113
  • Postal Code / City00280 Helsinki
  • Region / CountryUusimaa, Finland
  • Direct Telephone+358 9 4245 1890

Engineering & Dispatch

  • Sales & Quotessales@ground-store.pro
  • Technical Deskengineering@ground-store.pro
  • Operating HoursMon–Fri, 08:00–16:30 EET
  • Dispatch HubVantaa / Vuosaari Cargo
  • Portal StatusCatalog Sync v4.2